CM Coaxial Vertical Antenna, converted with 4nec2 on 28-Nov-08 22:18
CM This "Franklin" array model was created by Linley Gumm,
CM K7HFD. Coaxial cable is modeled as a combination of
CM transmission line model, to represent the inside of the
CM coax, and a wire to represent the outside. The technique is
CM described in the EZNEC manual. See "Coaxial Cable,
CM Modeling" in the index.
CE
SY freq=144 ' Design frequency.
GW 1 1 0 0 3.24991861 9.99975e-3 0 3.24991861 6.10007e-5
GW 2 1 0 0 2.7699303 9.99975e-3 0 2.74993121 6.10007e-5
GW 3 1 0 0 2.2499438 9.99975e-3 0 2.26994338 6.10007e-5
GW 4 1 0 0 1.76995549 9.99975e-3 0 1.74995592 6.10007e-5
GW 5 1 0 0 1.24996899 9.99975e-3 0 1.26996761 6.10007e-5
GW 6 1 0 0 0.76998068 9.99975e-3 0 0.74998111 6.10007e-5
GW 7 1 0 0 0.24999404 9.99975e-3 0 0.26999299 6.10007e-5
GW 8 11 0 0 3.24991861 0 0 2.7699303 3.05003e-3
GW 9 11 9.99975e-3 0 2.74993121 9.99975e-3 0 2.26994338 3.05003e-3
GW 10 11 0 0 2.2499438 0 0 1.76995549 3.05003e-3
GW 11 11 9.99975e-3 0 1.74995592 9.99975e-3 0 1.26996761 3.05003e-3
GW 12 11 0 0 1.24996899 0 0 0.76998068 3.05003e-3
GW 13 11 9.99975e-3 0 0.74998111 9.99975e-3 0 0.26999299 3.05003e-3
GW 14 6 0 0 0.24999404 0 0 0 3.05003e-3
GW 15 1 0 0 0 9.99975e-3 0 9.99975e-3 6.10007e-5
GS 0 0 299.8/freq ' All in WL.
GE 0
TL 1 1 2 1 50 1.04095e0
TL 2 1 3 1 50 1.04095e0
TL 3 1 4 1 50 1.04095e0
TL 4 1 5 1 50 1.04095e0
TL 5 1 6 1 50 1.04095e0
TL 6 1 7 1 50 1.04095e0
TL 7 1 15 1 -50 1.04095e0
EX 6 15 1 0 1 0
GN 1
FR 0 1 0 0 144 0